Change Language
Opening Hours - Mon to Sat: 9 AM to 7PM
Call Us : 08045477961
Bomb Calorimeter- Automatic Type
Bomb Calorimeter- Automatic Type

Bomb Calorimeter- Automatic Type

MOQ : 1 Unit

Bomb Calorimeter- Automatic Type Specification

  • Equipment Type
  • Bomb Calorimeter - Automatic Type
  • Max Height
  • Approx. 400 mm
  • Response Time
  • Within 5 seconds
  • Interface Type
  • RS232/USB (optional)
  • Mounting Type
  • Bench top
  • Accuracy
  • 0.1% or better
  • Resolution
  • 0.01C
  • Usage
  • Industrial
  • Frequency
  • 50 Hz
  • Test Range
  • Up to 10,000 cal/g
  • Number of Specimens
  • 1
  • Humidity
  • Up to 85% RH
  • Product Type
  • Bomb Calorimeter- Automatic Type
  • Color
  • White
  • Gas Pressure
  • Up to 30 atm max
  • Specimen Size
  • 1 gm (typical sample)
  • Features
  • Automatic Oxygen Filling, Data Storage, Thermal Printer, Graphic Display
  • Operating Voltage
  • 230V AC
  • Automation Grade
  • Fully Automatic
  • Application
  • Determination of calorific value of solid and liquid fuels, coal, etc.
  • Power Supply
  • 230V AC, 50Hz
  • Port Size
  • Standard Gas Inlet Connection
  • Temperature
  • Ambient to 35C Operating
  • Measuring Range
  • 0-10,000 calories/gram
  • Display Type
  • Digital LCD/LED with print output
  • Capacity
  • 3000 ml (Calorimeter Vessel)
  • Machine Weight
  • Approx. 30 kg
  • Control Mode
  • Automatic
  • Data Export
  • PC connectivity with software
  • Safety Features
  • Automatic Over-pressure Cutoff, Leak Detection
  • Internal Memory
  • Up to 100 test results
  • Oxygen Filling Pressure
  • 30 atm (max.)
  • Water Jacket Volume
  • 10 litres
  • Printer Type
  • Thermal printer, built-in
  • Cooling Time
  • Approx. 20 minutes between tests
  • Ignition System
  • Automatic Electrical Ignition
 

Bomb Calorimeter- Automatic Type Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • FOB Port
  • INDIA
  • Payment Terms
  • Telegraphic Transfer (T/T), Cash in Advance (CID), Cash Advance (CA)
  • Supply Ability
  • 10 Units Per Day
  • Delivery Time
  • 10-15 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Main Domestic Market
  • All India
 

About Bomb Calorimeter- Automatic Type

This instrument is used to evaluate the heat of combustion of organic matter and the calorific value with sulfur content of solid & liquid fuel.

The most significant feature of this model is that it is microprocessor based with automatic Measurement & Calculation of Calorific value/Water Equivalent. In built Thermal Printer has PC Software for data record. Final Test report printout is given with date and time. 

Product Details:

Minimum Order Quantity

1 Unit

Automation Type

Automatic

Brand

Pap-Tech

Condition

New

Gcv Range

Up to 10,000 Kcal

Model

PAP-5055-B

Power Supply

220 V

Temperature Resolution

0.01 Degree Celcius

Display

Big Jumbo LCD 20x4 display

Printer

Yes- In built

Calculation

Automatic

Keypad

16 soft touch keypad

Software for Data Record

PC Software

Additional Information:

Item Code: PAP-5055-B

Packaging Details: (A) Packing & Forwarding Charges @ 3%

(B) Insurance & Freight to be covered by the buyer.

(C) GST : 28% HSN Code (8419)





Advanced Automatic Calorimetry for Reliable Results

This bomb calorimeter streamlines fuel analysis with fully automated sample processing, automatic oxygen filling, and built-in safety mechanisms. The system's high accuracy, automatic data handling, and graphical display ensure consistent and reliable results with minimal manual intervention, making it ideal for demanding industrial and laboratory environments.


Comprehensive Data Handling and Export Capabilities

With a capacity to store up to 100 test results and a built-in thermal printer, this calorimeter efficiently manages your test data. The RS232/USB interface enables easy export of data to connected PCs for analysis, documentation, and archiving, while the graphic digital display enhances user experience during operation.


Designed for Safety and Ease of Use

Safety features such as automatic over-pressure cutoff and leak detection provide an extra layer of protection during high-pressure oxygen filling, ensuring user safety and equipment longevity. The automatic ignition system and intuitive automatic control further simplify operation, reducing training time and operational errors.

FAQ's of Bomb Calorimeter- Automatic Type:


Q: How does the automatic bomb calorimeter determine the calorific value of fuels?

A: The bomb calorimeter operates by combusting a small specimen (typically 1 gram) of solid or liquid fuel in a high-pressure oxygen environment. The heat released is absorbed by water in the 10-litre jacket, and the temperature change is measured to precisely calculate the sample's calorific value.

Q: What safety features are included in this equipment?

A: This model includes automatic over-pressure cutoff and leak detection systems to safeguard against excessive pressure and potential leaks during oxygen filling, providing a safe working environment for laboratory personnel.

Q: When is it appropriate to use this calorimeter?

A: This equipment is ideally used in industrial and laboratory settings for the accurate analysis of the calorific value of various fuels-especially for research, quality control, and fuel certification processes.

Q: Where can the data from the calorimeter be exported or stored?

A: Test results can be stored in the device's internal memory (up to 100 results), printed via the built-in thermal printer, or exported to a computer using RS232/USB connectivity and compatible software for further analysis and record-keeping.

Q: What is the typical process for running a test with this bomb calorimeter?

A: To conduct a test, place approximately 1 gram of fuel specimen in the vessel, initiate automatic oxygen filling, and close the system. The calorimeter manages ignition, combustion, temperature monitoring, and data collection automatically, providing results within minutes.

Q: How do users benefit from the automatic control and built-in printer features?

A: Automatic control and the built-in printer minimize manual steps, reduce user error, and streamline documentation. Operators can conduct consistent tests with quick results and generate hard copies of data directly from the instrument for accurate record-keeping.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Environmental Testing Equipment Category

Fully Automatic Type Bomb Calorimeter

Fully Automatic Type Bomb Calorimeter

Price 250000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Control Mode : Automatic

Number of Specimens : 1

Color : Silver

Product Type : Fully Automatic Type Bomb Calorimeter

Laboratory Oven

Laboratory Oven

Price 30000 INR

Minimum Order Quantity : 1 Piece

Control Mode : Manual

Number of Specimens : 1

Color : White, Blue

Product Type : Laboratory Oven

Water and Soil Analysis Kit

Water and Soil Analysis Kit

Price 27000 INR

Minimum Order Quantity : 1 Piece

Control Mode : Digital

Number of Specimens : 1

Color : White

Product Type : Water and Soil Analysis Kit

BOD Incubator

BOD Incubator

Price 75000 INR

Minimum Order Quantity : 1 Piece

Control Mode : MANUAL

Number of Specimens : 1

Color : White

Product Type : BOD Incubator



Back to top